od marekmin » 23.05.2015 21:02
po dlhšom jazdení sa chyba vyskytla zvova! Nastalo zúfalstvo.
Mode $06 report generated by Torque for Android
================================================
VIN vozidla:Nie je k dispozícii
Výrobca motora:Neznáme
Kalibrácia ID vozidla:GED-746CFS4-5000
Test report:
------------------
MID:$01 TID:$01
Rich to Lean sensor threshold voltage(constant) - O2 Bank 1 Sensor 1
Max: 0,44969V Min: 0,44969V
Test result value: 0,44969V
PASS
----
MID:$01 TID:$02
Lean to Rich sensor threshold voltage(constant) - O2 Bank 1 Sensor 1
Max: 0,44969V Min: 0,44969V
Test result value: 0,44969V
PASS
----
MID:$01 TID:$07
Minimum sensor Voltage for test cycle(calculated) - O2 Bank 1 Sensor 1
Test incomplete or dependant test failed
--
MID:$01 TID:$08
Maximum sensor Voltage for test cycle(calculated) - O2 Bank 1 Sensor 1
Test incomplete or dependant test failed
--
MID:$02 TID:$01
Rich to Lean sensor threshold voltage(constant) - O2 Bank 1 Sensor 2
Max: 0,64514V Min: 0,64514V
Test result value: 0,64514V
PASS
----
MID:$02 TID:$02
Lean to Rich sensor threshold voltage(constant) - O2 Bank 1 Sensor 2
Max: 0,64514V Min: 0,64514V
Test result value: 0,64514V
PASS
----
MID:$02 TID:$07
Minimum sensor Voltage for test cycle(calculated) - O2 Bank 1 Sensor 2
Test incomplete or dependant test failed
--
MID:$02 TID:$08
Maximum sensor Voltage for test cycle(calculated) - O2 Bank 1 Sensor 2
Test incomplete or dependant test failed
--
MID:$21 TID:$80
- Catalyst Monitor Bank 1
Test incomplete or dependant test failed
--
MID:$41 TID:$81
- O2 Heater Monitor Bank 1 - Sensor 1
Test incomplete or dependant test failed
--
MID:$42 TID:$81
- O2 Heater Monitor Bank 1 - Sensor 2
Test incomplete or dependant test failed
--
MID:$01 TID:$01
Rich to Lean sensor threshold voltage(constant) - O2 Bank 1 Sensor 1
Max: 0,44969V Min: 0,44969V
Test result value: 0,44969V
PASS
----
MID:$01 TID:$02
Lean to Rich sensor threshold voltage(constant) - O2 Bank 1 Sensor 1
Max: 0,44969V Min: 0,44969V
Test result value: 0,44969V
PASS
----
MID:$01 TID:$07
Minimum sensor Voltage for test cycle(calculated) - O2 Bank 1 Sensor 1
Max: 0,40114V Min: 0V
Test result value: 0,08991V
PASS
----
MID:$01 TID:$08
Maximum sensor Voltage for test cycle(calculated) - O2 Bank 1 Sensor 1
Max: 1,07946V Min: 0,59634V
Test result value: 0,73956V
PASS
----
MID:$02 TID:$01
Rich to Lean sensor threshold voltage(constant) - O2 Bank 1 Sensor 2
Max: 0,64514V Min: 0,64514V
Test result value: 0,64514V
PASS
----
MID:$02 TID:$02
Lean to Rich sensor threshold voltage(constant) - O2 Bank 1 Sensor 2
Max: 0,64514V Min: 0,64514V
Test result value: 0,64514V
PASS
----
MID:$02 TID:$07
Minimum sensor Voltage for test cycle(calculated) - O2 Bank 1 Sensor 2
Max: 0,44969V Min: 0V
Test result value: 0,44969V
PASS
----
MID:$02 TID:$08
Maximum sensor Voltage for test cycle(calculated) - O2 Bank 1 Sensor 2
Max: 1,07946V Min: 0,44969V
Test result value: 0,79947V
PASS
----
Koniec reportu.